SpectraMax i3x Multi-Mode Microplate Reader Fluorescence spectrophotometry, UV-Vis, NIR, RAMAN, FT-IR, etc.

MOLECULAR DEVICES #039

 Molecular Devices Logo

Unlimited breadth of user-installable application modules expands research capabilities

The SpectraMax® i3x Multi-Mode Microplate Reader can perform a wide range of essential cell-based and biochemical assays using the included absorbance, fluorescence, and luminescence detection modes. With the SpectraMax® MiniMax™ 300 Imaging Cytometer, industry-leading SoftMax® Pro Software, and user-configurable detection modules, this unique reader enables users to add optional detection modules at any time to expand the reader’s capabilities and explore cellular pathways and protein expression on one microplate reader. This includes AlphaScreen/AlphaLisa, time-resolved fluorescence, TR-FRET/HTRF, fluorescence polarization, dual injectors, and western blot detection. Transmitted light and fluorescence channels offer the option to image stain-free or use cellular dyes to get a better view of cytotoxicity, cell proliferation, and phenotypic changes.

 

User-configurable applications

User-installable detection modules expand the reader’s detection capabilities to include AlphaScreen, time-resolved fluorescence, TR-FRET (including HTRF), fast kinetics with injectors, western blot detection, and more.

No-stain cell analysis

The StainFree™ Cell Detection Algorithm for brightfield cell segmentation enables cell counting and confluency measurement without destructive stains, simplifying the cell analysis workflow.

Multi-channel functionality

Two fluorescence detection channels on the MiniMax 300 cytometer enable the analysis of cell viability or cell toxicity assays, including viability assays and transfection efficiency.

Cellular pathway analysis

Cell confluence and cell viability imaging, western blot analysis, and quantitation of nucleic acids and protein, can be captured on one reader.

Spectral Optimization Wizard

This built-in technology enables users to optimize their assay in a single-step by quickly identifying the best excitation and emission wavelengths.

Auto Intensity Adjustment

Our patented technology acquires data over a wide dynamic range without the need to re-read the plate due to saturation effects. PMT gain adjustment is bypassed with the use of high-power LEDs as part of the Spectral Fusion Illumination.

Read more in the manufacturer's page.

CONTAINS

  • Capture flash assays with ease
  • Achieve unparalleled sensitivity
  • Increase fluorescence performance
MOLECULAR DEVICES #039

CLIMACELL 707 - EVO line Test and Heat Chambers, Furnaces

MMM #031

MMM Logo

The CLIMACELL® series was specially developed for applications, in which as far as possible exact and reproducible simulation of various environmental conditions is important, e.g. stability testing of components, packaging materials, food or chemicals, drugs, germination studies, plant cell or tissue cultures, insect cultures. This devices offers an interesting alternative to expensive testing chambers and testing rooms. Microprocessor controlled humidity assembly with powerful lighting system are warranty of the excellent homogene parameters for tests and growth conditions.

Characteristics

  • Laboratory incubator – it always creates the right climate
  • Chamber volume 707 litres
  • Temperature range: from 0°C to 100°C without humidity, from 10° C to 90° C with humidity
  • Patented cooling system (environment-friendly working medium R 134a) and air flow in the chamber ensure fast and accurate distribution of the selected temperature and humidity in the chamber and thus the ideal process of sample heating and reduction of moisture condensation in the chamber
  • Offers high operation comfort, precise temperature control, possibility of achieving extremely short times of temperature changes and short times of temperature and humidity equalization in the chamber after the door opening
  • Suitable for use in research on germs, plant or tissue cultures, insects, stability tests, etc.
  • Comfortable design with multi-processor Fuzzy logic control system, controls placed on a foil keyboard, process information displayed on LED display.
  • Wide selection of optional equipment and accessories
  • Output for connecting a printer or PC
  • Possibility of validation (IQ, OQ)

Read more in the manufacturer's page.

CONTAINS

  • Chamber volume 707 litres
  • laboratory incubator – it always creates the right climate
  • patented cooling system
MMM #031

CLIMACELL 707 - EVO line Test and Heat Chambers, Furnaces

MMM #031

 MMM Logo

The CLIMACELL® series was specially developed for applications, in which as far as possible exact and reproducible simulation of various environmental conditions is important, e.g. stability testing of components, packaging materials, food or chemicals, drugs, germination studies, plant cell or tissue cultures, insect cultures. This devices offers an interesting alternative to expensive testing chambers and testing rooms. Microprocessor controlled humidity assembly with powerful lighting system are warranty of the excellent homogene parameters for tests and growth conditions.

Characteristics

  • Laboratory incubator – it always creates the right climate
  • Chamber volume 707 litres
  • Temperature range: from 0°C to 100°C without humidity, from 10° C to 90° C with humidity
  • Patented cooling system (environment-friendly working medium R 134a) and air flow in the chamber ensure fast and accurate distribution of the selected temperature and humidity in the chamber and thus the ideal process of sample heating and reduction of moisture condensation in the chamber
  • Offers high operation comfort, precise temperature control, possibility of achieving extremely short times of temperature changes and short times of temperature and humidity equalization in the chamber after the door opening
  • Suitable for use in research on germs, plant or tissue cultures, insects, stability tests, etc.
  • Comfortable design with multi-processor Fuzzy logic control system, controls placed on a foil keyboard, process information displayed on LED display.
  • Wide selection of optional equipment and accessories
  • Output for connecting a printer or PC
  • Possibility of validation (IQ, OQ)

Read more in the manufacturer's page.

CONTAINS

  • Chamber volume 707 litres
  • laboratory incubator – it always creates the right climate
  • patented cooling system
MMM #031

GC-IMS-SILOX Special Techniques for insertion and Detection in GC (Headspace, Thermal Desorption, Vacuum UV, FT-IR)

GAS Dortmund #100

G.A.S. Dortmund Logo

Precise on-site Quantification of Siloxanes in Biogas, Landfill and Digester Gas

The GC-IMS-SILOX is a stand-alone device that has been developed for user-friendly and reliable one-site measurements of siloxanes in biogas, landfill or sewage gas.

The device has a straight-forward single-click menu and can alternatively be run as online monitoring system testing the gas automatically in user defined intervals. Results of siloxanes, silica (SiO2) same as silicon (‘Total Si’) are stored on its flash memory and shown on the 6.4" touchscreen or the ‘Total Si’ value is transferρed via 4–20mA or MODBUS (TCP). To run the system it only takes power and nitrogen (cylinder or N2 -generator).

Advantages of G.A.S.’ GC-IMS-SILOX for  siloxane analysis: 

  • On-site measurements with “one-click” menu
  • On-line/continuous monitoring at set intervals
  • Very low detection limits (µg/m3) with 'total silica' (SiO2) and 'total silicon' (Si) results transferred via4-20mA or MODBUS (TCP)
  • High reproducibility and accuracy
  • Very low running and maintenance costs 

Flexible sampling is assured by an integrated pump and a six-port valve to either test from gas sample-bags or as preferred directly from the gas pipe via a by-pass. Condensation water can be trapped by the use of an optional (GENIE-) filter.

Its menu allows that an on-site test can securely be carried out by non-specialists. Alternatively it can be used as a 24/7 based on-line monitoring tool to test for individual siloxanes at their relevant concentration levels to take immediate on-site decisions. 

Read more in the manufacturer's page.

CONTAINS

  • 2-fold separation of GC and IMS
  • High reproducibility
  • One-point calibration functionality
GAS Dortmund #100

GC-IMS-SILOX Special Techniques for insertion and Detection in GC (Headspace, Thermal Desorption, Vacuum UV, FT-IR)

GAS Dortmund #100

 G.A.S. Dortmund Logo

Precise on-site Quantification of Siloxanes in Biogas, Landfill and Digester Gas

The GC-IMS-SILOX is a stand-alone device that has been developed for user-friendly and reliable one-site measurements of siloxanes in biogas, landfill or sewage gas.

The device has a straight-forward single-click menu and can alternatively be run as online monitoring system testing the gas automatically in user defined intervals. Results of siloxanes, silica (SiO2) same as silicon (‘Total Si’) are stored on its flash memory and shown on the 6.4" touchscreen or the ‘Total Si’ value is transferρed via 4–20mA or MODBUS (TCP). To run the system it only takes power and nitrogen (cylinder or N2 -generator).

 

Advantages of G.A.S.’ GC-IMS-SILOX for  siloxane analysis: 

  • On-site measurements with “one-click” menu
  • On-line/continuous monitoring at set intervals
  • Very low detection limits (µg/m3) with 'total silica' (SiO2) and 'total silicon' (Si) results transferred via4-20mA or MODBUS (TCP)
  • High reproducibility and accuracy
  • Very low running and maintenance costs 

Flexible sampling is assured by an integrated pump and a six-port valve to either test from gas sample-bags or as preferred directly from the gas pipe via a by-pass. Condensation water can be trapped by the use of an optional (GENIE-) filter.

Its menu allows that an on-site test can securely be carried out by non-specialists. Alternatively it can be used as a 24/7 based on-line monitoring tool to test for individual siloxanes at their relevant concentration levels to take immediate on-site decisions. 

Read more in the manufacturer's page.

CONTAINS

  • 2-fold separation of GC and IMS
  • High reproducibility
  • One-point calibration functionality
GAS Dortmund #100

GC-IMS Special Techniques for insertion and Detection in GC (Headspace, Thermal Desorption, Vacuum UV, FT-IR)

GAS Dortmund #099

G.A.S. Dortmund Logo

The Gas Chromatograph - Ion Mobility Spectrometer (GC-IMS) of G.A.S. combines the high selectivity of a Gas Chromatograph with the extraordinary sensitivity of an IMS (typically low ppbv range)

The technical configurations with gas chromatographic (GC) columns include standard capillary (15-60m) or multi-capillary of various stationary phases that are selected acc. to the requirements of the analytical assignments.

The GC-IMS has integrated temperature and flow controller allowing firmware steered ramping to better separate highly volatile compounds and shorten run times which is decisive QC related assignments. The availability of positive same as negative ionization modes enables the applicability for a wide range of substances e.g. ketones, aldehydes, alcohols, amines, phosphor organics same as chlorinated or halogenated compounds. 

The integrated six-port valve secures a very flexible sampling of gases. Further to that all relevant measurement parameters for method development are easy to access so that the operator can optimize the system with regard to his specific application.

Applications

  • Odour Source Identification and Support of industrial Odour Management
  • Sub-ppm Sulfur Quantification
  • Propellant Gases Testing

The GC-IMS operates isotherm in a range of 40-80°C and >100°C for baking out (cleaning).  The GC-IMS provides an automatic data acquisition on the device and when connected to a PC 3-D data visualization and analysis by G.A.S. software suite called Laboratory Analytical Viewer (LAV).  Besides the possibility of quantifying single marker compounds additional software plug-ins allow to easy detect the appearance of new compounds or the differences of concentrations of existing compounds. The result classifies differences from a selected reference (golden standard) to quickly characterize e.g. the quality of a sample.

An easy menu, manual or automatic operation modes as well as data acquisition, -analysis on board plus analogue data output via 4-20mA current loop facilitate a remote online process control. While the standard configuration of the GC-IMS requires N2 or synthetic for its operation it can alternatively be equipped with a circular gas flow unit (CGFU) to be independent from any external gas supply. All these characteristics together represent highest flexibility and make up the usefulness of the GC-IMS as analytical online and/or on-site tool.

Through this the device can be applied for several analytical measurements e.g. testing for residual solvents, impurities from production, off-flavour detection, product or ingredients authentication, bad smell or TICs monitoring from industrial plants, perfume and cosmetics on human skin, etc.

Read more in the manufacturer's page.

CONTAINS

  • Stand alone operation due to integrated computer unit
  • High reproducibility
  • Heating mode up to 100 °C for fast cleaning of the system
GAS Dortmund #099

GC-IMS Special Techniques for insertion and Detection in GC (Headspace, Thermal Desorption, Vacuum UV, FT-IR)

GAS Dortmund #099

 G.A.S. Dortmund Logo

The Gas Chromatograph - Ion Mobility Spectrometer (GC-IMS) of G.A.S. combines the high selectivity of a Gas Chromatograph with the extraordinary sensitivity of an IMS (typically low ppbv range)

The technical configurations with gas chromatographic (GC) columns include standard capillary (15-60m) or multi-capillary of various stationary phases that are selected acc. to the requirements of the analytical assignments.

The GC-IMS has integrated temperature and flow controller allowing firmware steered ramping to better separate highly volatile compounds and shorten run times which is decisive QC related assignments. The availability of positive same as negative ionization modes enables the applicability for a wide range of substances e.g. ketones, aldehydes, alcohols, amines, phosphor organics same as chlorinated or halogenated compounds. 

The integrated six-port valve secures a very flexible sampling of gases. Further to that all relevant measurement parameters for method development are easy to access so that the operator can optimize the system with regard to his specific application.

 

Applications

  • Odour Source Identification and Support of industrial Odour Management
  • Sub-ppm Sulfur Quantification
  • Propellant Gases Testing

The GC-IMS operates isotherm in a range of 40-80°C and >100°C for baking out (cleaning).  The GC-IMS provides an automatic data acquisition on the device and when connected to a PC 3-D data visualization and analysis by G.A.S. software suite called Laboratory Analytical Viewer (LAV).  Besides the possibility of quantifying single marker compounds additional software plug-ins allow to easy detect the appearance of new compounds or the differences of concentrations of existing compounds. The result classifies differences from a selected reference (golden standard) to quickly characterize e.g. the quality of a sample.

An easy menu, manual or automatic operation modes as well as data acquisition, -analysis on board plus analogue data output via 4-20mA current loop facilitate a remote online process control. While the standard configuration of the GC-IMS requires N2 or synthetic for its operation it can alternatively be equipped with a circular gas flow unit (CGFU) to be independent from any external gas supply. All these characteristics together represent highest flexibility and make up the usefulness of the GC-IMS as analytical online and/or on-site tool.

Through this the device can be applied for several analytical measurements e.g. testing for residual solvents, impurities from production, off-flavour detection, product or ingredients authentication, bad smell or TICs monitoring from industrial plants, perfume and cosmetics on human skin, etc.

Read more in the manufacturer's page.

CONTAINS

  • Stand alone operation due to integrated computer unit
  • High reproducibility
  • Heating mode up to 100 °C for fast cleaning of the system
GAS Dortmund #099

Syft Tracer Chromatography (HPLC, U(H)PLC, UPLC, SPE, GPC, Preparative LC, HPTLC, GC, Flash, etc.)

SYFT #122

Syft Logo

Industry-Scalable, Real-Time Trace Gas Analysis

Syft Tracer is next generation of SIFT-MS real-time trace gas detection designed to solve the most difficult analytical challenges. This advancement to SIFT-MS delivers trace-level detection sensitivity, unparalleled performance stability, superior selectivity, and highly reproducible, quantitative data.

Syft Tracer: The Industry Standard for Real-Time Contaminant Detection

Syft TracerTM is the latest advancement in real-time, direct injection mass spectrometry (MS) built to solve the most difficult analytical challenges faced within a variety of industries and applications.

This advancement to SIFT-MS delivers trace-level detection sensitivity, unparalleled performance stability, superior selectivity, and highly reproducible, quantitative data. Target multiple analytes in the same analysis without the need for sample prep or other time-consuming chromatography steps. Run chemically diverse compounds in one method, or between numerous methods, with a single instrument configuration that does not require changeover or reequilibration steps. Syft Tracer is engineered for durabality and optimized for high-throughput environments where 24/7 operation is the standard. Never miss a product or environmental contamination event again.

Benefits of Syft Tracer

  • Trace level multi-analyte detection sensitivity
  • Highly selective and quantitative
  • No chromatography or pre-concentration required
  • Fine Auto Retune for optimal signal levels
  • Performance Authenticator for superior analytical stability
  • Hardware advancements to maximize system lifetime
  • System drive optimized for 24/7 data collection
  • Easy to operate and interpret data

Read more in the manufacturer's page.

CONTAINS

  • Easy to operate and interpret data
  • No chromatography or pre-concentration required
  • Highly selective and quantitative
SYFT #122

Syft Tracer Chromatography (HPLC, U(H)PLC, UPLC, SPE, GPC, Preparative LC, HPTLC, GC, Flash, etc.)

SYFT #122

 Syft Logo

Industry-Scalable, Real-Time Trace Gas Analysis

Syft Tracer is next generation of SIFT-MS real-time trace gas detection designed to solve the most difficult analytical challenges. This advancement to SIFT-MS delivers trace-level detection sensitivity, unparalleled performance stability, superior selectivity, and highly reproducible, quantitative data.

 

Syft Tracer: The Industry Standard for Real-Time Contaminant Detection

Syft TracerTM is the latest advancement in real-time, direct injection mass spectrometry (MS) built to solve the most difficult analytical challenges faced within a variety of industries and applications.

This advancement to SIFT-MS delivers trace-level detection sensitivity, unparalleled performance stability, superior selectivity, and highly reproducible, quantitative data. Target multiple analytes in the same analysis without the need for sample prep or other time-consuming chromatography steps. Run chemically diverse compounds in one method, or between numerous methods, with a single instrument configuration that does not require changeover or reequilibration steps. Syft Tracer is engineered for durabality and optimized for high-throughput environments where 24/7 operation is the standard. Never miss a product or environmental contamination event again.

Benefits of Syft Tracer

  • Trace level multi-analyte detection sensitivity
  • Highly selective and quantitative
  • No chromatography or pre-concentration required
  • Fine Auto Retune for optimal signal levels
  • Performance Authenticator for superior analytical stability
  • Hardware advancements to maximize system lifetime
  • System drive optimized for 24/7 data collection
  • Easy to operate and interpret data

Read more in the manufacturer's page.

CONTAINS

  • Easy to operate and interpret data
  • No chromatography or pre-concentration required
  • Highly selective and quantitative
SYFT #122

Syft Explorer Chromatography (HPLC, U(H)PLC, UPLC, SPE, GPC, Preparative LC, HPTLC, GC, Flash, etc.)

SYFT #124

Syft Logo

Syft Explorer provides everything needed to make critical decisions quickly, anywhere on-site.

The Syft Explorer offers real-time and selective analysis, presented in a mobile solution. This allows investigation of contamination sites and short-term chemical leaks for critical concentration levels. Detect crucial volatile emissions at their source such as airborne molecular contaminants. Syft Explorer comes with built-in data acquisition and processing capabilities, facilitating quick decision-making from sample measurements. It provides high resolution data collection at locations of interest without the need for chromatography or sample preparation.

A complete solution for versatile, point of interest mobile monitoring

Syft Explorer is an all-in-one solution designed for environmental, indoor air and semiconductor applications. It delivers high sensitivity, exceptional performance stability, and highly reproducible data. With its mobile functionality, it enables rapid, selective, and reliable analysis of contaminants at ambient air sites. Syft Explorer offers a unified configuration for analyzing volatile organic compounds and inorganics with a single method or between multiple methods. It enables continuous, on-line analysis and provides a dedicated user-friendly interface for instrument control, status information and data visualization.

Benefits of Syft Explorer

  • Highly selective and quantitative
  • Easy to operate and interpret data
  • One configuration for multiple, diverse analyses
  • Trace level multi-analyte detection sensitivity
  • No chromatography or sample preparation required
  • Extensive compound library that can be used to
    create customized analyte targeting methods

Read more in the manufacturer's page.

CONTAINS

  • No chromatography or sample preparation required
  • One configuration for multiple, diverse analyses
  • Highly selective and quantitative
SYFT #124